български english

Compact I/O

Compact I/O DRT2CRT1SRT2
DRT2CRT1SRT2
Network connection DeviceNet with baud rate auto-select, open-style push-in terminal block.CompoNet with baud rate auto-select, latching IDC connectors on flat cableCompoBus/S, high-speed mode (0.8 ms, 100m)+ long-distance mode (6 ms, 500m)
I/O types 8/16 DI+extension, 8/16 DO+extenstion, 16 relay out, 4 AI (V/I, TC, Pt100), 2 AO (V/I),16 DI+extension, 16 DO+extenstion, 4 AI, 2 AO, 2 DI, 2 DO.4/8/16 DI, 4/8/16 DO, 8/16 relay out, 4 AI (V/I)2 AO (V/I)
I/O Connection technology M3 screw terminals (1 or 3-wire DI)M3 screw terminals, eCON/RITS sensor connectorsM3 screw terminals (1 or 3-wire DI)
Smart features I/O and power supply diagnostics. Operation timers and counters per I/O point. Analog value calculations and alarms.I/O and power supply diagnostics. Operation timers and counters for each I/O point. Analog value calculations and alarms.I/O isolation, status indication
Ingress Protection class IP20 (DIN rail mounting in cabinets)IP20 (DIN rail mounting in cabinets)IP20 (DIN rail mounting in cabinets)
Size in mm (HxDxW)main units: 50 x 50 x 115/125; 8/16 pt. expansion: 50 x 50 x 66/94main units: 50 x 50 x 115; 8/16 pt. expansion: 50 x 50 x 66/94; 2-point slaves: 50 x 30 x 50DI/DO units : 50 x 48 x 80/105/180; Relay units: 50 x 50 x 100/155;analog units : 50 x 48 x 105
Пълно описаниевижвижвиж